Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
1.
J Biol Chem ; 299(5): 104697, 2023 05.
Article in English | MEDLINE | ID: covidwho-2300740

ABSTRACT

The processing of the Coronavirus polyproteins pp1a and pp1ab by the main protease Mpro to produce mature proteins is a crucial event in virus replication and a promising target for antiviral drug development. Mpro cleaves polyproteins in a defined order, but how Mpro and/or the polyproteins determine the order of cleavage remains enigmatic due to a lack of structural information about polyprotein-bound Mpro. Here, we present the cryo-EM structures of SARS-CoV-2 Mpro in an apo form and in complex with the nsp7-10 region of the pp1a polyprotein. The complex structure shows that Mpro interacts with only the recognition site residues between nsp9 and nsp10, without any association with the rest of the polyprotein. Comparison between the apo form and polyprotein-bound structures of Mpro highlights the flexible nature of the active site region of Mpro, which allows it to accommodate ten recognition sites found in the polyprotein. These observations suggest that the role of Mpro in selecting a preferred cleavage site is limited and underscores the roles of the structure, conformation, and/or dynamics of the polyproteins in determining the sequence of polyprotein cleavage by Mpro.


Subject(s)
Coronavirus 3C Proteases , Polyproteins , Proteolysis , SARS-CoV-2 , Humans , Polyproteins/metabolism , SARS-CoV-2/metabolism , Coronavirus 3C Proteases/metabolism
2.
BMC Infect Dis ; 23(1): 110, 2023 Feb 23.
Article in English | MEDLINE | ID: covidwho-2261264

ABSTRACT

BACKGROUND: Rapid determination of an individual's antibody status can be beneficial in understanding an individual's immune response to SARS-CoV-2 and for initiation of therapies that are only deemed effective in sero-negative individuals. Antibody lateral flow tests (LFTs) have potential to address this need as a rapid, point of care test. METHODS: Here we present a proof-of-concept evaluation of eight LFT brands using sera from 95 vaccinated individuals to determine sensitivity for detecting vaccination generated antibodies. Samples were analysed on eight different brands of antibody LFT and an automated chemiluminescent microparticle immunoassay (CMIA) that identifies anti-spike antibodies which was used as our reference standard. RESULTS: All 95 (100%) participants tested positive for anti-spike antibodies by the chemiluminescent microparticle immunoassay (CMIA) reference standard post-dose two of their SARS-CoV-2 vaccine: BNT162b2 (Pfizer/BioNTech, n = 60), AZD1222 (AstraZeneca, n = 31), mRNA-1273 (Moderna, n = 2) and Undeclared Vaccine Brand (n = 2). Sensitivity increased from dose one to dose two in six out of eight LFTs with three tests achieving 100% sensitivity at dose two in detecting anti-spike antibodies. CONCLUSIONS: These tests are demonstrated to be highly sensitive to detect raised antibody levels in vaccinated individuals. RDTs are low cost and rapid alternatives to ELISA based systems.


Subject(s)
COVID-19 Vaccines , COVID-19 , Humans , BNT162 Vaccine , ChAdOx1 nCoV-19 , COVID-19/diagnosis , COVID-19/prevention & control , SARS-CoV-2 , Antibodies, Viral , Vaccination
3.
Sci Rep ; 13(1): 3887, 2023 03 08.
Article in English | MEDLINE | ID: covidwho-2259559

ABSTRACT

The emergence of severe acute respiratory syndrome 2 (SARS-CoV-2) variants of concern (VOCs), with mutations linked to increased transmissibility, vaccine escape and virulence, has necessitated the widespread genomic surveillance of SARS-CoV-2. This has placed a strain on global sequencing capacity, especially in areas lacking the resources for large scale sequencing activities. Here we have developed three separate multiplex high-resolution melting assays to enable the identification of Alpha, Beta, Delta and Omicron VOCs. The assays were evaluated against whole genome sequencing on upper-respiratory swab samples collected during the Alpha, Delta and Omicron [BA.1] waves of the UK pandemic. The sensitivities of the eight individual primer sets were all 100%, and specificity ranged from 94.6 to 100%. The multiplex HRM assays have potential as a tool for high throughput surveillance of SARS-CoV-2 VOCs, particularly in areas with limited genomics facilities.


Subject(s)
COVID-19 , Humans , SARS-CoV-2/genetics , Mutation , Biological Assay , Genomics
4.
Lancet Infect Dis ; 2022 Oct 19.
Article in English | MEDLINE | ID: covidwho-2231863

ABSTRACT

BACKGROUND: The antiviral drug molnupiravir was licensed for treating at-risk patients with COVID-19 on the basis of data from unvaccinated adults. We aimed to evaluate the safety and virological efficacy of molnupiravir in vaccinated and unvaccinated individuals with COVID-19. METHODS: This randomised, placebo-controlled, double-blind, phase 2 trial (AGILE CST-2) was done at five National Institute for Health and Care Research sites in the UK. Eligible participants were adult (aged ≥18 years) outpatients with PCR-confirmed, mild-to-moderate SARS-CoV-2 infection who were within 5 days of symptom onset. Using permuted blocks (block size 2 or 4) and stratifying by site, participants were randomly assigned (1:1) to receive either molnupiravir (orally; 800 mg twice daily for 5 days) plus standard of care or matching placebo plus standard of care. The primary outcome was the time from randomisation to SARS-CoV-2 PCR negativity on nasopharyngeal swabs and was analysed by use of a Bayesian Cox proportional hazards model for estimating the probability of a superior virological response (hazard ratio [HR]>1) for molnupiravir versus placebo. Our primary model used a two-point prior based on equal prior probabilities (50%) that the HR was 1·0 or 1·5. We defined a priori that if the probability of a HR of more than 1 was more than 80% molnupiravir would be recommended for further testing. The primary outcome was analysed in the intention-to-treat population and safety was analysed in the safety population, comprising participants who had received at least one dose of allocated treatment. This trial is registered in ClinicalTrials.gov, NCT04746183, and the ISRCTN registry, ISRCTN27106947, and is ongoing. FINDINGS: Between Nov 18, 2020, and March 16, 2022, 1723 patients were assessed for eligibility, of whom 180 were randomly assigned to receive either molnupiravir (n=90) or placebo (n=90) and were included in the intention-to-treat analysis. 103 (57%) of 180 participants were female and 77 (43%) were male and 90 (50%) participants had received at least one dose of a COVID-19 vaccine. SARS-CoV-2 infections with the delta (B.1.617.2; 72 [40%] of 180), alpha (B.1.1.7; 37 [21%]), omicron (B.1.1.529; 38 [21%]), and EU1 (B.1.177; 28 [16%]) variants were represented. All 180 participants received at least one dose of treatment and four participants discontinued the study (one in the molnupiravir group and three in the placebo group). Participants in the molnupiravir group had a faster median time from randomisation to negative PCR (8 days [95% CI 8-9]) than participants in the placebo group (11 days [10-11]; HR 1·30, 95% credible interval 0·92-1·71; log-rank p=0·074). The probability of molnupiravir being superior to placebo (HR>1) was 75·4%, which was less than our threshold of 80%. 73 (81%) of 90 participants in the molnupiravir group and 68 (76%) of 90 participants in the placebo group had at least one adverse event by day 29. One participant in the molnupiravir group and three participants in the placebo group had an adverse event of a Common Terminology Criteria for Adverse Events grade 3 or higher severity. No participants died (due to any cause) during the trial. INTERPRETATION: We found molnupiravir to be well tolerated and, although our predefined threshold was not reached, we observed some evidence that molnupiravir has antiviral activity in vaccinated and unvaccinated individuals infected with a broad range of SARS-CoV-2 variants, although this evidence is not conclusive. FUNDING: Ridgeback Biotherapeutics, the UK National Institute for Health and Care Research, the Medical Research Council, and the Wellcome Trust.

5.
Microbiol Spectr ; : e0201222, 2022 Nov 30.
Article in English | MEDLINE | ID: covidwho-2137462

ABSTRACT

The COVID-19 pandemic has led to the commercialization of many antigen-based rapid diagnostic tests (Ag-RDTs), requiring independent evaluations. This report describes the clinical evaluation of the Novel Coronavirus 2019-nCoV Antigen Test (Colloidal Gold) (Beijing Hotgen Biotech Co., Ltd.), at two sites within Brazil and one in the United Kingdom. The collected samples (446 nasal swabs from Brazil and 246 nasopharyngeal samples from the UK) were analyzed by the Ag-RDT and compared to reverse transcription-quantitative PCR (RT-qPCR). Analytical evaluation of the Ag-RDT was performed using direct culture supernatants of SARS-CoV-2 strains from the wild-type (B.1), Alpha (B.1.1.7), Delta (B.1.617.2), Gamma (P.1), and Omicron (B.1.1.529) lineages. An overall sensitivity and specificity of 88.2% (95% confidence interval [CI], 81.3 to 93.3) and 100.0% (95% CI, 99.1 to 100.0), respectively, were obtained for the Brazilian and UK cohorts. The analytical limit of detection was determined as 1.0 × 103 PFU/mL (Alpha), 2.5 × 102 PFU/mL (Delta), 2.5 × 103 PFU/mL (Gamma), and 1.0 × 103 PFU/mL (Omicron), giving a viral copy equivalent of approximately 2.1 × 104 copies/mL, 9.0 × 105 copies/mL, 1.7 × 106 copies/mL, and 1.8 × 105 copies/mL for the Ag-RDT, respectively. Overall, while a higher sensitivity was claimed by the manufacturers than that found in this study, this evaluation finds that the Ag-RDT meets the WHO minimum performance requirements for sensitivity and specificity of COVID-19 Ag-RDTs. This study illustrates the comparative performance of the Hotgen Ag-RDT across two global settings and considers the different approaches in evaluation methods. IMPORTANCE Since the beginning of the SARS-CoV-2 pandemic, we have witnessed growing numbers of antigen rapid diagnostic tests (Ag-RDTs) being brought to market. In the United Kingdom, this was somewhat controlled indirectly as the government offered free tests from a small number of companies. However, as this has now ceased, individuals are responsible for their own acquisition of test kits. Similarly in Brazil, as of January 2022, pharmacies and other health care retailers are permitted to sell Ag-RDTs directly to the community. Many of these Ag-RDTs have not been externally evaluated, and results are not readily available to the public. Thus, there is now a need for a transparent evaluation of Ag-RDTs with both analytical and clinical evaluation. We present an independent review of the Novel Coronavirus 2019-nCoV Antigen Test (Colloidal Gold) (Beijing Hotgen Biotech Co., Ltd.), at two sites within Brazil and one in the United Kingdom.

6.
Nat Commun ; 13(1): 7284, 2022 Nov 26.
Article in English | MEDLINE | ID: covidwho-2133432

ABSTRACT

Molnupiravir is an antiviral, currently approved by the UK Medicines and Healthcare products Regulatory Agency (MHRA) for treating at-risk COVID-19 patients, that induces lethal error catastrophe in SARS-CoV-2. How this drug-induced mechanism of action might impact the emergence of resistance mutations is unclear. To investigate this, we used samples from the AGILE Candidate Specific Trial (CST)-2 (clinical trial number NCT04746183). The primary outcomes of AGILE CST-2 were to measure the drug safety and antiviral efficacy of molnupiravir in humans (180 participants randomised 1:1 with placebo). Here, we describe the pre-specified exploratory virological endpoint of CST-2, which was to determine the possible genomic changes in SARS-CoV-2 induced by molnupiravir treatment. We use high-throughput amplicon sequencing and minor variant analysis to characterise viral genomics in each participant whose longitudinal samples (days 1, 3 and 5 post-randomisation) pass the viral genomic quality criteria (n = 59 for molnupiravir and n = 65 for placebo). Over the course of treatment, no specific mutations were associated with molnupiravir treatment. We find that molnupiravir significantly increased the transition:transversion mutation ratio in SARS-CoV-2, consistent with the model of lethal error catastrophe. This study highlights the utility of examining intra-host virus populations to strengthen the prediction, and surveillance, of potential treatment-emergent adaptations.


Subject(s)
COVID-19 Drug Treatment , SARS-CoV-2 , Humans , Antiviral Agents/pharmacology , Antiviral Agents/therapeutic use , Genomics , SARS-CoV-2/genetics
7.
PLoS One ; 17(9): e0275294, 2022.
Article in English | MEDLINE | ID: covidwho-2054373

ABSTRACT

The COVID-19 pandemic created the need for large-scale testing of populations. However, most laboratories do not have sufficient testing capacity for mass screening. We evaluated pooled testing of samples, as a strategy to increase testing capacity in Lao PDR. Samples of consecutive patients were tested in pools of four using the Xpert Xpress SARS CoV-2 assay. Positive pools were confirmed by individual testing, and we describe the performance of the test and savings achieved. We also diluted selected positive samples to describe its effect on the assays CT values. 1,568 patients were tested in 392 pools of four. 361 (92.1%) pools were negative and 31 (7.9%) positive. 29/31 (93.5% (95%CI 77-99%) positive pools were confirmed by individual testing of the samples but, in 2/31 (6.5%) the four individual samples were negative, suggesting contamination. Pools with only one positive sample had higher CT values (lower RNA concentrations) than the respective individual samples, indicating a dilution effect, which suggested an increased risk of false negative results with dilutions >1:10. However, this risk may be low if the prevalence of infection is high, when pools are more likely to contain more than one positive sample. Pooling saved 67% of cartridges and substantially increased testing capacity. Pooling samples increased SARS-CoV-2 testing capacity and resulted in considerable cartridge savings. Given the need for high-volume testing, countries may consider implementation of pooling for SARS-CoV-2 screening.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , COVID-19/epidemiology , COVID-19 Testing , Humans , Laos/epidemiology , Pandemics , RNA
8.
Rev Soc Bras Med Trop ; 55: e0016, 2022.
Article in English | MEDLINE | ID: covidwho-1892410

ABSTRACT

BACKGROUND: The emergence of variants of concern (VOCs) requires an ongoing assessment of the performance of antigen lateral flow tests (Ag-RDTs). The limit of detection (LOD) of 32 Ag-RDTs was evaluated using the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) Gamma variant. METHODS: Ag-RDTs were performed according to the manufacturer's instructions with a clinical isolate of the Gamma variant. RESULTS: Twenty-eight of the 32 Ag-RDTs exceeded the World Health Organization criteria. CONCLUSIONS: This comprehensive analytical evaluation of Ag-RDTs demonstrated that the test performance was maintained with Gamma VOC.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , Humans , Sensitivity and Specificity
9.
J Med Microbiol ; 71(2)2022 Feb.
Article in English | MEDLINE | ID: covidwho-1709252

ABSTRACT

Introduction. The importance of human saliva in aerosol-based transmission of SARS-CoV-2 is now widely recognized. However, little is known about the efficacy of virucidal mouthwash formulations against emergent SARS-CoV-2 variants of concern and in the presence of saliva.Hypothesis. Mouthwashes containing virucidal actives will have similar inactivation effects against multiple SARS-CoV-2 variants of concern and will retain efficacy in the presence of human saliva.Aim. To examine in vitro efficacy of mouthwash formulations to inactivate SARS-CoV-2 variants.Methodology. Inactivation of SARS-CoV-2 variants by mouthwash formulations in the presence or absence of human saliva was assayed using ASTM International Standard E1052-20 methodology.Results. Appropriately formulated mouthwashes containing 0.07 % cetylpyridinium chloride but not 0.2 % chlorhexidine completely inactivated SARS-CoV-2 (USA-WA1/2020, Alpha, Beta, Gamma, Delta) up to the limit of detection in suspension assays. Tests using USA-WA1/2020 indicates that efficacy is maintained in the presence of human saliva.Conclusions. Together these data suggest cetylpyridinium chloride-based mouthwashes are effective at inactivating SARS-CoV-2 variants. This indicates potential to reduce viral load in the oral cavity and mitigate transmission via salivary aerosols.


Subject(s)
Cetylpyridinium , Mouthwashes , SARS-CoV-2 , Saliva , COVID-19 , Cetylpyridinium/pharmacology , Humans , Mouthwashes/pharmacology , SARS-CoV-2/drug effects , Saliva/virology
10.
Sci Rep ; 12(1): 1416, 2022 01 26.
Article in English | MEDLINE | ID: covidwho-1655626

ABSTRACT

The control of the COVID-19 pandemic in the UK has necessitated restrictions on amateur and professional sports due to the perceived infection risk to competitors, via direct person to person transmission, or possibly via the surfaces of sports equipment. The sharing of sports equipment such as tennis balls was therefore banned by some sport's governing bodies. We sought to investigate the potential of sporting equipment as transmission vectors of SARS-CoV-2. Ten different types of sporting equipment, including balls from common sports, were inoculated with 40 µl droplets containing clinically relevant concentrations of live SARS-CoV-2 virus. Materials were then swabbed at time points relevant to sports (1, 5, 15, 30, 90 min). The amount of live SARS-CoV-2 recovered at each time point was enumerated using viral plaque assays, and viral decay and half-life was estimated through fitting linear models to log transformed data from each material. At one minute, SARS-CoV-2 virus was recovered in only seven of the ten types of equipment with the low dose inoculum, one at five minutes and none at 15 min. Retrievable virus dropped significantly for all materials tested using the high dose inoculum with mean recovery of virus falling to 0.74% at 1 min, 0.39% at 15 min and 0.003% at 90 min. Viral recovery, predicted decay, and half-life varied between materials with porous surfaces limiting virus transmission. This study shows that there is an exponential reduction in SARS-CoV-2 recoverable from a range of sports equipment after a short time period, and virus is less transferrable from materials such as a tennis ball, red cricket ball and cricket glove. Given this rapid loss of viral load and the fact that transmission requires a significant inoculum to be transferred from equipment to the mucous membranes of another individual it seems unlikely that sports equipment is a major cause for transmission of SARS-CoV-2. These findings have important policy implications in the context of the pandemic and may promote other infection control measures in sports to reduce the risk of SARS-CoV-2 transmission and urge sports equipment manufacturers to identify surfaces that may or may not be likely to retain transferable virus.


Subject(s)
COVID-19/transmission , SARS-CoV-2/physiology , COVID-19/virology , Half-Life , Humans , Linear Models , SARS-CoV-2/isolation & purification , Sports Equipment , Surface Properties
11.
J Infect ; 84(3): 355-360, 2022 03.
Article in English | MEDLINE | ID: covidwho-1560123

ABSTRACT

BACKGROUND: There are an abundance of commercially available lateral flow assays (LFAs) that detect antibodies to SARS-CoV-2. Whilst these are usually evaluated by the manufacturer, externally performed diagnostic accuracy studies to assess performance are essential. Herein we present an evaluation of 12 LFAs. METHODS: Sera from 100 SARS-CoV-2 reverse-transcriptase polymerase chain reaction (RT-PCR) positive participants were recruited through the FASTER study. A total of 105 pre-pandemic sera from participants with other infections were included as negative samples. RESULTS: At presentation sensitivity against RT-PCR ranged from 37.4 to 79% for IgM/IgG, 30.3-74% for IgG, and 21.2-67% for IgM. Sensitivity for IgM/IgG improved ≥ 21 days post symptom onset for 10/12 tests. Specificity ranged from 74.3 to 99.1% for IgM/IgG, 82.9-100% for IgG, and 75.2-98% for IgM. Compared to the EuroImmun IgG enzyme-linked immunosorbent assay (ELISA), sensitivity and specificity ranged from 44.6 to 95.4% and 85.4-100%, respectively. CONCLUSION: There are many LFAs available with varied sensitivity and specificity. Understanding the diagnostic accuracy of these tests will be vital as we come to rely more on the antibody status of a person moving forward, and as such manufacturer-independent evaluations are crucial.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Viral , COVID-19/diagnosis , Humans , Immunoassay , Immunoglobulin G , Immunoglobulin M , Sensitivity and Specificity
12.
Sci Rep ; 11(1): 22493, 2021 11 18.
Article in English | MEDLINE | ID: covidwho-1526101

ABSTRACT

The COVID-19 pandemic caused by SARS-CoV-2 has infected millions worldwide, therefore there is an urgent need to increase our diagnostic capacity to identify infected cases. Although RT-qPCR remains the gold standard for SARS-CoV-2 detection, this method requires specialised equipment in a diagnostic laboratory and has a long turn-around time to process the samples. To address this, several groups have recently reported the development of loop-mediated isothermal amplification (LAMP) as a simple, low cost and rapid method for SARS-CoV-2 detection. Herein we present a comparative analysis of three LAMP-based assays that target different regions of the SARS-CoV-2: ORF1ab RdRP, ORF1ab nsp3 and Gene N. We perform a detailed assessment of their sensitivity, kinetics and false positive rates for SARS-CoV-2 diagnostics in LAMP or RT-LAMP reactions, using colorimetric or fluorescent detection. Our results independently validate that all three assays can detect SARS-CoV-2 in 30 min, with robust accuracy at detecting as little as 1000 RNA copies and the results can be visualised simply by color changes. Incorporation of RT-LAMP with fluorescent detection further increases the detection sensitivity to as little as 100 RNA copies. We also note the shortcomings of some LAMP-based assays, including variable results with shorter reaction time or lower load of SARS-CoV-2, and false positive results in some experimental conditions and clinical saliva samples. Overall for RT-LAMP detection, the ORF1ab RdRP and ORF1ab nsp3 assays have faster kinetics for detection but varying degrees of false positives detection, whereas the Gene N assay exhibits no false positives in 30 min reaction time, which highlights the importance of optimal primer design to minimise false-positives in RT-LAMP. This study provides validation of the performance of LAMP-based assays as a rapid, highly sensitive detection method for SARS-CoV-2, which have important implications in development of point-of-care diagnostics for SARS-CoV-2.


Subject(s)
COVID-19 Nucleic Acid Testing , COVID-19 , Molecular Diagnostic Techniques , Nucleic Acid Amplification Techniques , SARS-CoV-2/genetics , Saliva/metabolism , Adult , COVID-19/diagnosis , COVID-19/genetics , COVID-19/metabolism , Female , Humans , Male , Saliva/virology
13.
Sci Rep ; 11(1): 18313, 2021 09 15.
Article in English | MEDLINE | ID: covidwho-1412108

ABSTRACT

In the context of the coronavirus disease 2019 (COVID-19) pandemic there has been an increase of the use of antigen-detection rapid diagnostic tests (Ag-RDT). The performance of Ag-RDT vary greatly between manufacturers and evaluating their analytical limit of detection (LOD) has become high priority. Here we describe a manufacturer-independent evaluation of the LOD of 19 marketed Ag-RDT using live SARS-CoV-2 spiked in different matrices: direct culture supernatant, a dry swab, and a swab in Amies. Additionally, the LOD using dry swab was investigated after 7 days' storage at - 80 °C of the SARS-CoV-2 serial dilutions. An LOD of ≈ 5.0 × 102 pfu/ml (1.0 × 106 genome copies/ml) in culture media is defined as acceptable by the World Health Organization. Fourteen of 19 Ag-RDTs (ActiveXpress, Espline, Excalibur, Innova, Joysbio, Mologic, NowCheck, Orient, PanBio, RespiStrip, Roche, Standard-F, Standard-Q and Sure-Status) exceeded this performance criteria using direct culture supernatant applied to the Ag-RDT. Six Ag-RDT were not compatible with Amies media and a decreased sensitivity of 2 to 20-fold was observed for eleven tests on the stored dilutions at - 80 °C for 7 days. Here, we provide analytical sensitivity data to guide appropriate test and sample type selection for use and for future Ag-RDT evaluations.


Subject(s)
Antigens, Viral/immunology , COVID-19 Serological Testing/methods , COVID-19/diagnosis , SARS-CoV-2/immunology , Animals , Antibodies, Viral/analysis , Chlorocebus aethiops , Humans , Limit of Detection , Reagent Kits, Diagnostic , Specimen Handling , Vero Cells
14.
Lancet Reg Health Am ; 3: 100076, 2021 Nov.
Article in English | MEDLINE | ID: covidwho-1401693

ABSTRACT

BACKGROUND: Detailed information on how socio-economic characteristics are related to COVID-19 incident cases and maternal deaths is needed. We investigated the spatial distribution of COVID-19 cases and maternal deaths in Brazil and their association with social determinants of health. METHODS: This was a population-based ecological study with a spatial analysis of all cases and deaths of COVID-19 in the obstetric population. Data on COVID-19 cases and deaths in the obstetric population, social vulnerability, health inequities, and health system capacity at the municipal level were obtained from several publicly sources in Brazil. A Bayesian empirical local model was used to identify fluctuations of the indicators. Spatial statistic tests were used to identity the spatial clusters and measure the municipalities' risk of COVID-19 in the obstetric population. Beta regression was used to characterise the association between socio-economic indicators and the burden of COVID-19. FINDINGS: A total of 13,858 cases and 1,396 deaths due to COVID-19 were recorded in Brazil from March 2020 to June 2021. There was a variation in the number of cases per municipality, with 105 municipalities with rates from 2,210 to 3,884 cases and 45 municipalities with rates from 3,884 to 7,418 cases per 100,000 live births. The maternal mortality ratio also varied widely across municipalities. There was a spatial dependence on smoothed maternal mortality rates (I Moran 0•10; P = 0•010), and 15 municipalities had higher risk of maternal deaths. Municipalities characterized by lower health resources and higher socioeconomic inequalities presented the highest rates of incidence and maternal mortality by COVID-19. INTERPRETATION: In Brazil, COVID-19 cases and deaths in the obstetric population had a heterogeneous geographical distribution, with well-defined spatial clusters mostly located in the countryside. Municipalities with a high degree of socioeconomic dissimilarities showed higher maternal mortality rates than areas with better social and infrastructure indicators. FUNDING: None.

15.
PLoS Negl Trop Dis ; 15(7): e0009551, 2021 07.
Article in English | MEDLINE | ID: covidwho-1301918

ABSTRACT

BACKGROUND: Individuals infected with SARS-CoV-2 develop neutralising antibodies. We investigated the proportion of individuals with SARS-CoV-2 neutralising antibodies after infection and how this proportion varies with selected covariates. METHODOLOGY/PRINCIPAL FINDINGS: This systematic review and meta-analysis examined the proportion of individuals with SARS-CoV-2 neutralising antibodies after infection and how these proportions vary with selected covariates. Three models using the maximum likelihood method assessed these proportions by study group, covariates and individually extracted data (protocol CRD42020208913). A total of 983 reports were identified and 27 were included. The pooled (95%CI) proportion of individuals with neutralising antibodies was 85.3% (83.5-86.9) using the titre cut off >1:20 and 83.9% (82.2-85.6), 70.2% (68.1-72.5) and 54.2% (52.0-56.5) with titres >1:40, >1:80 and >1:160, respectively. These proportions were higher among patients with severe COVID-19 (e.g., titres >1:80, 84.8% [80.0-89.2], >1:160, 74.4% [67.5-79.7]) than those with mild presentation (56.7% [49.9-62.9] and 44.1% [37.3-50.6], respectively) and lowest among asymptomatic infections (28.6% [17.9-39.2] and 10.0% [3.7-20.1], respectively). IgG and neutralising antibody levels correlated poorly. CONCLUSIONS/SIGNIFICANCE: 85% of individuals with proven SARS-CoV-2 infection had detectable neutralising antibodies. This proportion varied with disease severity, study setting, time since infection and the method used to measure antibodies.


Subject(s)
Antibodies, Neutralizing/blood , Antibodies, Viral/blood , COVID-19/immunology , SARS-CoV-2/immunology , Acute Disease , COVID-19/epidemiology , Convalescence , Humans , Prevalence
17.
Bone Jt Open ; 2(2): 134-140, 2021 Feb.
Article in English | MEDLINE | ID: covidwho-1102371

ABSTRACT

AIMS: Restarting planned surgery during the COVID-19 pandemic is a clinical and societal priority, but it is unknown whether it can be done safely and include high-risk or complex cases. We developed a Surgical Prioritization and Allocation Guide (SPAG). Here, we validate its effectiveness and safety in COVID-free sites. METHODS: A multidisciplinary surgical prioritization committee developed the SPAG, incorporating procedural urgency, shared decision-making, patient safety, and biopsychosocial factors; and applied it to 1,142 adult patients awaiting orthopaedic surgery. Patients were stratified into four priority groups and underwent surgery at three COVID-free sites, including one with access to a high dependency unit (HDU) or intensive care unit (ICU) and specialist resources. Safety was assessed by the number of patients requiring inpatient postoperative HDU/ICU admission, contracting COVID-19 within 14 days postoperatively, and mortality within 30 days postoperatively. RESULTS: A total of 1,142 patients were included, 47 declined surgery, and 110 were deemed high-risk or requiring specialist resources. In the ten-week study period, 28 high-risk patients underwent surgery, during which 68% (13/19) of Priority 2 (P2, surgery within one month) patients underwent surgery, and 15% (3/20) of P3 (< three months) and 16% (11/71) of P4 (> three months) groups. Of the 1,032 low-risk patients, 322 patients underwent surgery. Overall, 21 P3 and P4 patients were expedited to 'Urgent' based on biopsychosocial factors identified by the SPAG. During the study period, 91% (19/21) of the Urgent group, 52% (49/95) of P2, 36% (70/196) of P3, and 26% (184/720) of P4 underwent surgery. No patients died or were admitted to HDU/ICU, or contracted COVID-19. CONCLUSION: Our widely generalizable model enabled the restart of planned surgery during the COVID-19 pandemic, without compromising patient safety or excluding high-risk or complex cases. Patients classified as Urgent or P2 were most likely to undergo surgery, including those deemed high-risk. This model, which includes assessment of biopsychosocial factors alongside disease severity, can assist in equitably prioritizing the substantial list of patients now awaiting planned orthopaedic surgery worldwide. Cite this article: Bone Jt Open 2021;2(2):134-140.

18.
Emerg Infect Dis ; 27(3): 719-727, 2021 03.
Article in English | MEDLINE | ID: covidwho-1100025

ABSTRACT

GeneXpert-based testing with Xpert MTB/RIF or Ultra assays is essential for tuberculosis diagnosis. However, testing may be affected by cartridge and staff shortages. More efficient testing strategies could help, especially during the coronavirus disease pandemic. We searched the literature to systematically review whether GeneXpert-based testing of pooled sputum samples achieves sensitivity and specificity similar to testing individual samples; this method could potentially save time and preserve the limited supply of cartridges. From 6 publications, we found 2-sample pools using Xpert MTB/RIF had 87.5% and 96.0% sensitivity (average sensitivity 94%; 95% CI 89.0%-98.0%) (2 studies). Four-sample pools averaged 91% sensitivity with Xpert MTB/RIF (2 studies) and 98% with Ultra (2 studies); combining >4 samples resulted in lower sensitivity. Two studies reported that pooling achieved 99%-100% specificity and 27%-31% in cartridge savings. Our results show that pooling may improve efficiency of GeneXpert-based testing.


Subject(s)
COVID-19/epidemiology , Molecular Diagnostic Techniques , Mycobacterium tuberculosis/isolation & purification , Sputum/microbiology , Tuberculosis/diagnosis , Cost-Benefit Analysis , Humans , Mycobacterium tuberculosis/genetics , SARS-CoV-2 , Sensitivity and Specificity , Specimen Handling
SELECTION OF CITATIONS
SEARCH DETAIL